KRYLON,DIVISION OF SHERWIN-WILLIAMS COMPANY -- 1501 GLOSSY WHITE INDUSTRIAL MAINTENANCE & TOUCH UP SPRAY -- -
=====================  Product Identification  =====================

Product ID:1501 GLOSSY WHITE INDUSTRIAL MAINTENANCE & TOUCH UP SPRAY
MSDS Date:03/01/1995
FSC:NIIN:Submitter:D DG
Status Code:A
=== Responsible Party ===
Company Name:KRYLON,DIVISION OF SHERWIN-WILLIAMS COMPANY
Address:31500 SOLON RD.
City:SOLON
State:OH
ZIP:44139
Country:US
Info Phone Num:800-797-3332
Emergency Phone Num:216-292-7400
Resp. Party Other MSDS Num.:IM/KRI1
CAGE:EO392
=== Contractor Identification ===
Company Name:KRYLON,DIVISION OF SHERWIN-WILLIAMS COMPANY
Address:31500 SOLON RD.
Box:City:SOLON
State:OH
ZIP:44139
Country:US
Phone:800-247-3266
CAGE:EO392
Company Name:NASCO INTL INC., NASCO DIV
Address:901 JANESVILL AVE
Box:City:FORT ATKINSON
State:WI
ZIP:53538-0901
Country:US
Phone:920-563-2446
Contract Num:MDA414-99-A-0001-0137
CAGE:33089

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
= Wt:13.
OSHA PEL:1800 MG/M3;1000 PPM

Ingred Name:BUTANE
CAS:106-97-8
RTECS #:EJ4200000
= Wt:7.
OSHA PEL:800 PPM
ACGIH TLV:1900 MG/M3;800 PPM

Ingred Name:ETHYLBENZENE
CAS:100-41-4
RTECS #:DA0700000
= Wt:2.
OSHA PEL:435 MG/M3;100 PPM
ACGIH TLV:434 MG/M3;100 PPM
ACGIH STEL:543 MG/M3;125 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:XYLENE
CAS:1330-20-7
RTECS #:ZE2100000
= Wt:11.
OSHA PEL:100 PPM
ACGIH TLV:434 MG/M3;100 PPM
ACGIH STEL:651 MG/M3;150 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:1-BUTANOL
CAS:71-36-3
RTECS #:EO1400000
= Wt:2.
OSHA PEL:300 MG/M3;100 PPM
ACGIH STEL:C152 MG/M3;C50 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:ACETONE
CAS:67-64-1
RTECS #:AL3150000
= Wt:35.
OSHA PEL:2400 MG/M3;1000 PPM
ACGIH TLV:1780 MG/M3;750 PPM
ACGIH STEL:2380 MG/M3;1000 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:METHYL ETHYL KETONE
CAS:78-93-3
RTECS #:EL6475000
= Wt:4.
OSHA PEL:590 MG/M3;200 PPM
ACGIH TLV:590 MG/M3;200 PPM
ACGIH STEL:885 MG/M3;300 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:1-METHOXY-2-PROPYL ACETATE OR 1-METHYL-2-PROPANOL ACETATE
CAS:108-65-6
RTECS #:AI8925000
= Wt:7.

Ingred Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
= Wt:7.
OSHA PEL:15 MG/M3
ACGIH TLV:10 MG/M3

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:IRRITATION OF EYE, SKIN & RESPIRATORY
    SYSTEM. MAY CAUSE NERVOUS SYSTEM DEPRESSION. EXTREME OVEREXPOSURE
    MAY RESULT IN UNCONSCIOUSNESS & POSSIBLY DEATH. CHRONIC: PROLONGED
    & REPEATED EXPOSURE TO SOLVEN T INGREDIENTS MAY CAUSE ADVERSE
    EFFECTS TO THE LIVER, URINARY, BLOOD-FORMING, CARDIOVASCULAR &
    REPRODUCTIVE SYSTEMS. METHYL ETHYLKETONE MAY INCREASE THE NERVOUS
    SYSTEM EFFECTS OF OTHER SOLVENTS. REPOR TS HAVE ASSOCIATED REPEATED
    & PROLONGED OVEREXPOSUSE TO SOLVENTS WITH PERMANENT BRAIN & NERVOUS
    SYSTEM DAMAGE.
Explanation of Carcinogenicity:NO INGREDIENT IN THESE PRODUCT IS AN
    IARC, NTP OR OSHA LISTED CARCINOGEN. RATS EXPOSED TO TITANIUM
    DIOXIDE DUST AT 250 MG/M3 DEVELOPED LUNG CANCER, HOWEVER, SUCH
    EXPOSURE LEVELS ARE NOT ATTAINABLE IN  THE WORKPLACE.
Effects of Overexposure:HEADACHE, DIZZINESS, NAUSEA, LOSS OF
    COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO VAPORS. SPRAY
    MISTS. REDNESS & ITCHING OR BURNING SENSATION MAY INDICATE EYE OR
    EXCESSIVE SKIN EXPOSURE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

=======================  First Aid Measures  =======================

First Aid:IF INHALED: REMOVE FROM EXPOSURE.RESTORE BREATHING. KEEP WARM
    & QUIET. IF ON SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP AND
    WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE.  IF IN
    EYES:  FLUSH EYES WITH LARGE AMOUNTS OF WATER FOR 15 MINUTES. GET
    MEDICAL ATTENTION.	IF SWALLOWED: GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:<-17.6C, 0.F
Lower Limits:0.9
Upper Limits:12.8
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT INCLUDING
    SELF-CONTAINED BREATHING APPARATUS SHOULD BE USED. WATER SPRAY MAY
    BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLE IS PREFERABLE.WATER
    MAY BE USED TO COOL CLOSED CONTA INERS TO PREVENT PRESSURE BUILD UP
    AND POSSIBLE AUTOIGNITION OR EXPLOSION WHEN EXPOSED TO EXTREME
    HEAT.
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELECTRIC EQUIPMENT,
    SPARK & OPEN FLAME.CLOSED CONTAINER MAY EXPLODE WHEN EXPOSED TO
    EXTREME HEAT. APPLICATION TO HOT SURFACE REQUIRE SPECIAL
    PRECAUTION. EMERGENCY CONDITION OVEREXPO SURE TO DECOMPOSITION
    PRODUCT MAY CAUSE A HEATH HAZARD. SYMPTOM MAY NOT BE IMMEDIATELY
    APPARENT. OBTAIN MEDICAL AID.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH ABSORBENT.
Neutralizing Agent:NO DATA PROVIDED BY RESPONSIBLE PARTY.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTENTS ARE EXTREMELY FLAMMABLE. KEEP
    AWAY FROM HEAT, SPARKS, AND OPEN FLAME. VAPORS WILL ACCUMULATE
    READILY AND MAY IGNITE EXPLOSIVELY. KEEP AREA VENTILATED. DO NOT
    SMOKE. TURN OFF ALL SOURCES OF IG NITION.
Other Precautions:CONSULT NFPA CODE 30B-LEVEL 3 AEROSOL, PRODUCT 1310
    LEVEL 2 AEROSOLS. USE APPROVED BONDING & GROUNDING PROCEDURES.
    CONTENTS UNDER PRESSURE. DO NOT PUNCTURE, INCINERATE OR EXPOSE TO
    TEMPERATURES OVER 1 20F. HEAT FROM SUNLIGHT, RADIATOR, STOVE, HOT
    WATER ETC MAY CAUSE CONTAINER TO BURST. KEEP OUT OF RE ACH OF
    CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
    APPLICABLE LIMITS BY VENTILATION, WEAR  A PROPERLY FITTED ORGANIC
    VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA FOR PROTECTION
    AGAINST MATERIALS I N THE INGREDIENTS SECTION. WHEN SANDING OR
    ABRADING THE DRIED FILM, WEAR A DUST/MIST RESPIRATOR BY NIOSH/MSHA
    FOR PROTECTION AGAINST NON-VOLATILE MATERIAL.
Ventilation:LOCAL PREFERED.GENERAL ACCEPTABLE IF THE EXPOSURE TO
    MATERIAL IN INGREDIENTS IS MAINTAINED BELOW APPLICABLE EXPOSURE
    LIMITS.
Protective Gloves:NONE UNDLESS REPEATED EXPOSURE THEN CHEMICAL
    RESISTANT.
Eye Protection:SAFETY SPECTACLES WITH UNPERFORATED SIDESHIELDS.
Other Protective Equipment:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Work Hygienic Practices:USE ONLY WITH ADEQUATE VENTILATION. AVOID
    BREATHING VAPOR AND SPRAY MIST. AVOID CONTACT WITH SKIN AND
    EYE.WASH HANDS AFTER USING.
Supplemental Safety and Health
NO DATA PROVIDED BY RESPONSIBLE PARTY.

==================  Physical/Chemical Properties  ==================

HCC:V3
Boiling Pt:B.P. Text:<0 - 302F
Vapor Density:>AIR
Volatile Org Content %:81
Evaporation Rate & Reference:>1 (ETHER=1)
Appearance and Odor:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NO DATA PROVIDED BY RESPONSIBLE PARTY.
Hazardous Decomposition Products:CARBON DIOXIDE AND CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

===================  Toxicological Information	===================

Toxicological Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=====================  Ecological Information  =====================

Ecological:NO DATA PROVIDED BY RESPONSIBLE PARTY.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE FROM THIS PRODUCT MAY BE HAZARDOUS AS
    DEFINED UNDER RCRA (40 CFR 261). WASTE MUST BE TESTED FOR
    IGNITABILITY TO DETERMINE THE APPLICABLE EPA HAZARDOUS WASTE
    NUMBERS. DISPOSE OF IN ACCORDANCE WIT H FEDERAL, STATE, AND LOCAL
    REGULATIONS REGARDING POLLUTION. DO NOT INCINERATE.

===================  MSDS Transport Information  ===================

Transport Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.

=====================  Regulatory Information  =====================

SARA Title III Information:INGREDIENTS SUBJECT TO THE REPORTING
    REQUIREMENTS OF SARA TITLE III, SECTION 313, 40 CFR 372.65 C:
    ETHYLBENZENE,  ACETONE, XYLENE, METHYL ETHYL KETONE, 1-BUTANOL.
Federal Regulatory Information:NO DATA PROVIDED BY RESPONSIBLE PARTY.
State Regulatory Information:CALIFORNIA PROPOSITION 65: THIS PRODUCT
    CONTAINS A CHEMICAL(S) KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
    CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.